Strictly control the on-off sequence of fiber laser cutting machine

During the operation of the laser cutting machine, if the starting sequence of the fiber laser cutting machine is strictly controlled, the risk of condensation can be reduced and the failure of the machine can be reduced!

① Check whether there are any items in the operation range of the machine tool that affect the safe operation of the machine tool

② Turn on the main power switch and each branch control power switch of the fiber laser

③ Turn on the voltage stabilizer and check whether the operation status of the voltage stabilizer is normal

④ Turn on the power switch of the fiber laser, and let the fiber laser operate for more than 30 minutes with its own air conditioner or internal defroster

⑤ Turn on the air compressor when the power switch of the fiber laser is turned on for 20 minutes, and check whether the air compressor operates normally

⑥ Open the control air valve of the air circuit, open the cold dryer, check whether the cold dryer operates normally, and check whether the air pressure is normal

⑦ Open the cutting auxiliary gas control valve according to the cutting needs, and check whether the cutting auxiliary gas pressure is normal

⑧ Turn on the machine tool power switch, press the power on button to start the machine tool control system, and the machine tool will return to the original point after the control system starts normally

⑨ Turn on the water chiller after the power switch of the fiber laser is turned on for more than 30 minutes, and check whether the water chiller operates normally

⑩ After the actual temperature of the high and low temperature water of the water chiller reaches the set temperature ± 1 ℃, the fiber laser will be turned on high voltage, and check whether the fiber laser operates normallyV